INSPECTION
PROCEDURE
1. INSPECT FRONT SEAT FRAME WITH ADJUSTER LH
(a) Check operation of the seat frame (slide motor).
(1) w/ Memory: Check if the seat frame moves smoothly when the battery is connected to the slide motor connector terminals. OK:
If the result is not as specified, replace the front seat frame with adjuster LH. |
|
(2) w/o Memory: Check if the seat frame moves smoothly when the battery is connected to the slide motor connector terminals. OK:
If the result is not as specified, replace the front seat frame with adjuster LH. |
|
(b) Check operation of the seat frame (front vertical motor). (1) Check if the seat frame moves smoothly when the battery is connected to the front vertical motor connector terminals. OK:
If the result is not as specified, replace the front seat frame with adjuster LH. |
|
(c) Check operation of the seat frame (reclining motor). (1) Check if the seat frame moves smoothly when the battery is connected to the reclining motor connector terminals. OK:
If the result is not as specified, replace the front seat frame with adjuster LH. |
|
(d) Check operation of the seat frame (lifter motor). (1) Check if the seat frame moves smoothly when the battery is connected to the lifter motor connector terminals. OK:
If the result is not as specified, replace the front seat frame with adjuster LH. |
|
2. INSPECT FRONT SEAT FRAME WITH ADJUSTER RH
(a) Check operation of the seat frame (slide motor). (1) Check if the seat frame moves smoothly when the battery is connected to the slide motor connector terminals. OK:
If the result is not as specified, replace the front seat frame with adjuster RH. |
|
(b) Check operation of the seat frame (reclining motor). (1) Check if the seat frame moves smoothly when the battery is connected to the reclining motor connector terminals. OK:
If the result is not as specified, replace the front seat frame with adjuster RH. |
|
Transmission Fluid Temperature Sensor "A" Circuit Low Input (P0712,P0713)
DESCRIPTION
The Automatic Transmission Fluid (ATF) temperature sensor converts the fluid
temperature into a resistance value for use by the TCM.
The TCM applies a voltage to the temperature sensor through terminal THO1 of
the TCM.
The sensor resistanc ...
Pressure Sensor Circuit (B1423/23)
DESCRIPTION
This DTC is output when refrigerant pressure on the high pressure side is extremely
low (190 kPa (1.9 kgf/cm2, 28 psi) or less) or extremely high (3140 kPa (32.0 kgf/cm2,
455 psi) or more). The A/C pressure sensor is installed on the high pres ...
Problem Symptoms Table
PROBLEM SYMPTOMS TABLE
HINT:
Use the table below to help determine the cause of problem symptoms.
If multiple suspected areas are listed, the potential causes of the symptoms
are listed in order of probability in the "Suspected Area" ...