Toyota Venza manuals

Toyota Venza: Inspection

INSPECTION

PROCEDURE

1. INSPECT COMPRESSOR WITH PULLEY (SOLENOID VALVE)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

2 - 1

20°C (68°F)

10 to 11 Ω

If the resistance is not as specified, replace the A/C compressor (compressor with pulley).

Text in Illustration

*1

Component without harness connected

(A/C Compressor (Solenoid Valve))


On-vehicle Inspection
ON-VEHICLE INSPECTION PROCEDURE 1. INSPECT COMPRESSOR FOR METALLIC SOUND (a) Check if there is abnormal metallic sound from the A/C compressor (compressor with pulley) when the A/C switch is on a ...

Removal
REMOVAL PROCEDURE 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM 2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL NOTICE: When disconnecting the cable, some systems need to be initialized ...

Other materials about Toyota Venza:

Installation
INSTALLATION PROCEDURE 1. INSTALL STUD BOLT (for LH Side) (a) Using SST and a socket wrench (21 mm), install the stud bolt. Text in Illustration *1 Socket Wrench *2 ...

Rear Power Window LH Auto Up / Down Function does not Operate with Rear Power Window Switch LH
DESCRIPTION If the manual up/down function can be performed but the auto up/down function cannot, the fail-safe mode may be functioning. If the power window initialization (See page ) has not been performed, the auto up/down function will not operate. ...

Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4) (P2810)
DESCRIPTION Changing from 1st to 6th is performed by the TCM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid ...