CUSTOMIZE PARAMETERS
1. CUSTOMIZING FUNCTION WITH THE TECHSTREAM
HINT:
The following items can be customized.
NOTICE:
2. CUSTOMIZE
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menu: Body Electrical / Main Body or Illuminated Entry / Utility / Customize.
(e) Select the setting by referring to the table below.
Wireless Door Lock Control System|
Display (item) |
Default |
Function |
Setting |
|---|---|---|---|
|
Wireless Control |
ON |
Function that turns wireless door lock function ON/OFF |
ON or OFF |
|
Hazard Answer Back |
ON |
When the doors are locked by wireless operation, the hazard warning lights flash once. When the doors are unlocked by wireless operation, the hazard warning lights flash twice. |
ON or OFF |
|
Open Door Warning |
ON |
The buzzer sounds when LOCK is pressed when any of the doors are ajar. |
ON or OFF |
|
Unlock 2 Operation |
ON |
Function that unlocks driver side door when unlock switch on transmitter is pressed once, and unlocks all doors when pressed twice. If setting is OFF, pressing unlock switch once makes all doors unlock. |
ON or OFF |
|
Panic Function |
ON |
Function to operate theft deterrent system by continuously pressing panic switch on transmitter for 0.8 seconds |
ON or OFF |
|
Auto Lock Time |
60 s |
This function regulates the interval between unlocking and automatic relocking of doors. |
30 s, 60 s or 120 s |
|
Wireless Auto Lock |
ON |
This function turns the wireless auto lock function on or off. |
ON or OFF |
|
Wireless Buzzer Resp |
ON |
Wireless door lock buzzer response / ON or OFF |
ON or OFF |
|
Wireless Buzzer Vol |
Level7 |
Wireless door lock buzzer Volume |
Level7, Level6, Level5, Level4, Level3, Level2, Level1 or Level0 |
Operation Check
Problem Symptoms TableDisassembly
DISASSEMBLY
PROCEDURE
1. REMOVE ENGINE COVER JOINT
(a) Remove the 3 joints.
2. REMOVE SPARK PLUG
3. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Intake Side)
4. REMOVE CAMSHAFT TIM ...
Removal
REMOVAL
PROCEDURE
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-)
battery terminal to disable the SRS system.
NOTICE:
When disconnecting the cable, some systems ne ...
Registration
REGISTRATION
CAUTION / NOTICE / HINT
HINT:
Register a new recognition code when replacing the door control transmitter
or the door control receiver.
Add mode is used to retain the already registered codes while registering