DESCRIPTION
|
Detection Item |
Symptom |
Trouble Area |
|---|---|---|
|
Audio Receiver Assembly Communication Stop Mode |
|
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
HINT:
PROCEDURE
|
1. |
CHECK FOR OPEN IN CAN BUS WIRES (RADIO AND DISPLAY RECEIVER ASSEMBLY BRANCH WIRE) |
(a) Turn the ignition switch off.
|
(b) Disconnect the radio and display receiver assembly connector. Text in Illustration
|
|
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
|
E42-9 (CANH) - E42-10 (CANL) |
Ignition switch off |
54 to 69 Ω |
| NG | |
REPAIR OR REPLACE CAN BUS BRANCH WIRE OR CONNECTOR (RADIO AND DISPLAY RECEIVER ASSEMBLY BRANCH WIRE) |
|
|
2. |
CHECK HARNESS AND CONNECTOR (POWER SOURCE TERMINAL) |
(a) Disconnect the radio and display receiver assembly connector.
|
(b) Measure the voltage according to the value(s) in the table below. Standard Voltage:
|
|
| NG | |
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE TERMINAL) |
|
|
3. |
CHECK HARNESS AND CONNECTOR (GROUND TERMINAL) |
|
(a) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|
|
| OK | |
REPLACE RADIO AND DISPLAY RECEIVER ASSEMBLY |
| NG | |
REPAIR OR REPLACE HARNESS OR CONNECTOR (GROUND TERMINAL) |
Navigation Receiver Assembly Communication Stop Mode
Open in CAN Main Bus LineAuto Up Operation does not Fully Close Power Window (Jam Protection Function
is Activated)
DESCRIPTION
If a door glass or a power window regulator motor assembly does not operate smoothly,
the jam protection function may be triggered automatically, resulting in the auto
up function being unable to fully close the window.
HINT:
This symptom ma ...
Stop Light Switch
Components
COMPONENTS
ILLUSTRATION
Removal
REMOVAL
PROCEDURE
1. REMOVE STOP LIGHT SWITCH ASSEMBLY
(a) Disconnect the connector.
(b) Turn the stop light switch assembly countercl ...
Security Indicator Light Circuit
DESCRIPTION
Even when the theft deterrent system is in the disarmed state, the security indicator
blinks due to a signal output from the immobiliser system. The security indicator
blinks continuously due to a continuous signal received from the immobilise ...