INSTALLATION
PROCEDURE
1. INSTALL STARTER ASSEMBLY
|
(a) Install the starter with the 2 bolts. Torque: 37 N·m {377 kgf·cm, 27 ft·lbf} |
|
|
(b) Connect the starter connector. |
|
(c) Install the terminal nut and cover the nut with the cap.
Torque:
9.8 N·m {100 kgf·cm, 87 in·lbf}
2. INSTALL BATTERY
3. INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY
4. INSTALL COOL AIR INTAKE DUCT SEAL
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable
is reconnected (See page
).
Reassembly
Starting SystemIntake Manifold Runner Control Stuck Open (Bank 1) (P2004,P2006)
DESCRIPTION
The tumble control valve is built into the intake manifold. The tumble control
valve is composed of a position sensor and a DC motor. The DC motor opens and closes
the tumble control valve in response to signals from the ECM. The position sens ...
Installation
INSTALLATION
PROCEDURE
1. INSTALL GENERATOR ASSEMBLY
(a) Install the generator with the 2 bolts.
Torque:
52 N·m {530 kgf·cm, 38 ft·lbf}
(b) Install the wire harness clamp bracke ...
Data List / Active Test
DATA LIST / ACTIVE TEST
1. DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches,
sensors, actuators and other items to be read without removing any parts. This non-intrusive
inspection can be very useful bec ...