INSTALLATION
PROCEDURE
1. INSTALL STARTER ASSEMBLY
|
(a) Install the starter with the 2 bolts. Torque: 37 N·m {377 kgf·cm, 27 ft·lbf} |
|
|
(b) Connect the starter connector. |
|
(c) Install the terminal nut and cover the nut with the cap.
Torque:
9.8 N·m {100 kgf·cm, 87 in·lbf}
2. INSTALL BATTERY
3. INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY
4. INSTALL COOL AIR INTAKE DUCT SEAL
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable
is reconnected (See page
).
Reassembly
Starting SystemInspection
INSPECTION
PROCEDURE
1. INSPECT EVAPORATOR TEMPERATURE SENSOR
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
...
Evaporative Emission System Leak Detection Reference Orifice Low Flow (P043E,P043F,P2401,P2402,P2419)
DTC SUMMARY
DTC No.
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P043E
Reference orifice clogged
P043E, P ...
Data List / Active Test
DATA LIST / ACTIVE TEST
1. DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches,
sensors, actuators and other items to be read without removing any parts. This non-intrusive
inspection can be very useful bec ...