OPERATION CHECK
1. CHECK BASIC FUNCTIONS
(a) When the back door is partially closed, check that the motor operates to fully close (lock) the back door.
(b) Check that the back door can be opened.
(c) When the back door is partially closed and then the motor starts normal operation, push the back door opener switch assembly and pull up the back door to open it. At this time, check that the motor starts the reverse operation and then stops.
(d) Immediately after the back door is partially closed (the motor has not started operation yet), push the back door opener switch assembly to open the back door. Check that the motor does not operate at this time.
How To Proceed With Troubleshooting
InitializationTheft Deterrent System Presence Detection (B279C)
DESCRIPTION
If an ECM that is incompatible with the engine immobiliser system is installed,
the ECM stores this DTC.
DTC No.
DTC Detection Condition
Trouble Area
B279C
When an ECM that is incompa ...
Power Back Door cannot be Closed Using the Power Back Door Closer Switch
DESCRIPTION
When the power back door cannot be closed using the power back door closer switch,
either of the following may be malfunctioning: 1) power back door closer switch
circuit or 2) power back door ECU (power back door motor unit).
WIRING DIAGRAM
...
Installation
INSTALLATION
PROCEDURE
1. INSTALL NO. 1 FUEL TANK CUSHION
(a) Install 8 new No. 1 fuel tank cushions to the fuel tank.
2. INSTALL FUEL MAIN TUBE SUPPORT
(a) Install the fuel main tube su ...