OPERATION CHECK
1. CHECK BASIC FUNCTIONS
(a) When the back door is partially closed, check that the motor operates to fully close (lock) the back door.
(b) Check that the back door can be opened.
(c) When the back door is partially closed and then the motor starts normal operation, push the back door opener switch assembly and pull up the back door to open it. At this time, check that the motor starts the reverse operation and then stops.
(d) Immediately after the back door is partially closed (the motor has not started operation yet), push the back door opener switch assembly to open the back door. Check that the motor does not operate at this time.
How To Proceed With Troubleshooting
InitializationTrailer towing
Your vehicle is designed primarily as a passenger-and-load-carrying vehicle.
Towing a trailer can have an adverse impact on handling, performance, braking, durability,
and fuel consumption. For your safety and the safety of others, you must not overload
...
Installation
INSTALLATION
PROCEDURE
1. INSTALL GENERATOR ASSEMBLY
(a) Install the generator with the 2 bolts.
Torque:
52 N·m {530 kgf·cm, 38 ft·lbf}
(b) Install the wire harness clamp bracke ...
VSC OFF Indicator Light does not Come ON
DESCRIPTION
The skid control ECU is connected to the combination meter via CAN communication.
WIRING DIAGRAM
Refer to VSC OFF Indicator Light Remains ON (See page
).
PROCEDURE
1.
CHECK CAN COMMUNICATION SYSTEM
(a) Check ...