INITIALIZATION
1. INITIALIZE SLIDING ROOF ECU (SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY)
NOTICE:
HINT:
When the cable of the negative (-) battery terminal is disconnected and reconnected or the drive gear connector is disconnected and reconnected, the sliding roof drive gear (pulse sensor initial position setting) initialization is not necessary.
(a) Perform initialization according to the table below.
|
Condition of Sliding Roof |
Proceed to |
|---|---|
|
Auto slide open and tilt up functions do not operate |
Procedure A |
|
Sliding roof moves in reverse direction during slide close (tilt down) operation |
Procedure B |
|
Sliding roof does not stop at the correct fully closed position during tilt down operation |
Procedure C |
HINT:
Before performing initialization, make sure that there is no foreign matter on the guide rails and the guide rails are not deformed.
(1) Procedure A
NOTICE:
Make sure not to release the switch during the initialization. If the switch is released, perform the initialization again.
HINT:
The initialization process ends when this operation completes.
(2) Procedure B
(3) Procedure C
HINT:
The initialization process ends when this operation completes.
Operation Check
Problem Symptoms TableBack Door Motor Clutch Malfunction (B2225)
DESCRIPTION
When an electrical malfunction (open or short) is detected in the clutch circuit
of the power back door ECU (power back door motor unit) while the power back door
is operating, the power back door ECU (power back door motor unit) stores DTC B2 ...
Inspection
INSPECTION
PROCEDURE
1. INSPECT SHIFT SOLENOID VALVE SL
(a) Measure the resistance according to the value(s) in the table below.
Text in Illustration
*1
Shift Solenoid Valve SL
Standard Re ...
Oxygen (A/F) Sensor Signal Stuck Lean (Bank 1 Sensor 1) (P2195,P2196)
DESCRIPTION
HINT:
Although the DTC titles say oxygen sensor, these DTCs relate to the
air fuel ratio sensor.
Sensor 1 refers to the sensor mounted in front of the three-way catalytic
converter and located near the engine assembly.
...