PROCEDURE
|
1. |
CHECK CONDITION |
(a) Check if the system voice recognition level is low when recognizing a particular voice.
|
Result |
Proceed to |
|---|---|
|
System voice recognition level is low only for a particular voice. |
A |
|
System voice recognition level is low with any voice. |
B |
HINT:
System voice recognition level varies depending on voice and pronunciation. This is not a malfunction.
| A | |
END |
| B | |
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE |
Voice Guidance does not Function
Cellular Phone InspectionInspection
INSPECTION
PROCEDURE
1. INSPECT TIE ROD ASSEMBLY LH
(a) Secure the tie rod assembly LH in a vise.
(b) Install the nut to the stud bolt.
(c) Flip the ball joint back and forth 5 times.
(d) Set a to ...
Transmission Fluid Temperature Sensor "A" Performance (P0711)
DESCRIPTION
The Automatic Transmission Fluid (ATF) temperature sensor converts the fluid
temperature into a resistance value for use by the TCM.
The TCM applies a voltage to the temperature sensor through terminal THO1 of
the TCM.
The sensor resistance ...
Installation
INSTALLATION
PROCEDURE
1. INSTALL FRONT NO. 3 SPEAKER ASSEMBLY (for 13 Speakers)
(a) Engage the 3 claws to install the front No. 3 speaker assembly.
2. INSTALL FRONT PILLAR GARNISH CORNER PIECE (for ...