Be sure to record the current se ...
Oxygen (A/F) Sensor Signal Stuck Lean (Bank 1 Sensor 1) (P2195,P2196)
DESCRIPTION
HINT:
Although the DTC titles say oxygen sensor, these DTCs relate to the
air fuel ratio sensor.
Sensor 1 refers to the sensor mounted in front of the three-way catalytic
converter and located near the engine assembly.
...
Checking Monitor Status
CHECKING MONITOR STATUS
The purpose of the monitor result (mode 06) is to allow access to the results
of on-board diagnostic monitoring tests of specific components/systems that are
not continuously monitored. Examples are catalysts and evaporative emissi ...