PRECAUTION
1. NOTICE FOR INITIALIZATION:
NOTICE:
When disconnecting the cable from the negative (-) battery terminal, initialize the following systems after the cable is reconnected.
|
System Name |
See Procedure |
|---|---|
|
Back Door Closer System |
|
|
Power Back Door System |
2. PRECAUTIONS WHEN WORKING ON STEERING LOCK SYSTEM
(a) After replacing the steering lock ECU (steering lock actuator assembly), perform the key ID code registration.
(b) After replacing the steering lock ECU (steering lock actuator assembly), confirm the lock/unlock operation of the steering lock.
Operation Confirmation|
Steering Lock Condition |
Operation Condition |
|---|---|
|
Lock |
With the ignition switch off, open and close any door. |
|
Unlock |
Turn the ignition switch from off to ON or ACC. |
Parts LocationPIG Power Supply Voltage Malfunction (C1552)
DESCRIPTION
When a problem occurs in the power steering system, the power source relay circuit
is shut off to stop the power assist.
DTC No.
DTC Detection Condition
Trouble Area
C1552
PIG power s ...
IG2 Signal Malfunction (B2788)
DESCRIPTION
The steering lock ECU (steering lock actuator assembly) receives power from the
IG2 relay. When the voltage value indicated by the IG signal from the certification
ECU (smart key ECU assembly) equals to the voltage that is applied to the steer ...
Installation
INSTALLATION
PROCEDURE
1. INSTALL HEATED OXYGEN SENSOR
2. INSTALL FRONT EXHAUST PIPE ASSEMBLY
(a) Using a vernier caliper, measure the free length of the compression
springs.
Minimum Free Length:
41.5 mm (1.63 in.)
If the free l ...