CUSTOMIZE PARAMETERS
1. CUSTOMIZING FUNCTION WITH THE TECHSTREAM
HINT:
The following items can be customized.
NOTICE:
2. CUSTOMIZE
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menu: Body Electrical / Main Body or Illuminated Entry / Utility / Customize.
(e) Select the setting by referring to the table below.
Wireless Door Lock Control System|
Display (item) |
Default |
Function |
Setting |
|---|---|---|---|
|
Wireless Control |
ON |
Function that turns wireless door lock function ON/OFF |
ON or OFF |
|
Hazard Answer Back |
ON |
When the doors are locked by wireless operation, the hazard warning lights flash once. When the doors are unlocked by wireless operation, the hazard warning lights flash twice. |
ON or OFF |
|
Open Door Warning |
ON |
The buzzer sounds when LOCK is pressed when any of the doors are ajar. |
ON or OFF |
|
Unlock 2 Operation |
ON |
Function that unlocks driver side door when unlock switch on transmitter is pressed once, and unlocks all doors when pressed twice. If setting is OFF, pressing unlock switch once makes all doors unlock. |
ON or OFF |
|
Panic Function |
ON |
Function to operate theft deterrent system by continuously pressing panic switch on transmitter for 0.8 seconds |
ON or OFF |
|
Auto Lock Time |
60 s |
This function regulates the interval between unlocking and automatic relocking of doors. |
30 s, 60 s or 120 s |
|
Wireless Auto Lock |
ON |
This function turns the wireless auto lock function on or off. |
ON or OFF |
|
Wireless Buzzer Resp |
ON |
Wireless door lock buzzer response / ON or OFF |
ON or OFF |
|
Wireless Buzzer Vol |
Level7 |
Wireless door lock buzzer Volume |
Level7, Level6, Level5, Level4, Level3, Level2, Level1 or Level0 |
Operation Check
Problem Symptoms TableData List / Active Test
DATA LIST / ACTIVE TEST
1. READ DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches,
sensors, actuators and other items to be read without removing any parts. This non-intrusive
inspection can be very usefu ...
Installation
INSTALLATION
PROCEDURE
1. INSTALL SPIRAL WITH SENSOR CABLE SUB-ASSEMBLY
(a) Install the spiral with sensor cable sub-assembly (See page
).
NOTICE:
Do not replace the spiral cable with the battery connected and the engine
switch on (IG).
...
Installation
INSTALLATION
PROCEDURE
1. INSTALL GENERATOR ASSEMBLY
(a) Install the generator with the 2 bolts.
Torque:
52 N·m {530 kgf·cm, 38 ft·lbf}
(b) Install the wire harness clamp bracke ...