INSPECTION
PROCEDURE
1. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (w/o Smart Key System)
(a) Measure the voltage according to the value(s) in the table below. Text in Illustration
Standard Voltage:
HINT: Do not disconnect the shift lock control unit assembly connector. |
|
(b) Measure the resistance according to the value(s) in the table below. Text in Illustration
Standard Resistance:
HINT: Do not disconnect the shift lock control unit assembly connector. If the result is not as specified, replace the shift lever assembly. |
|
2. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (w/ Smart Key System)
(a) Measure the voltage according to the value(s) in the table below. Text in Illustration
Standard Voltage:
HINT: Do not disconnect the shift lock control unit assembly connector. If the result is not as specified, replace the shift lock control unit assembly. |
|
(b) Measure the resistance according to the value(s) in the table below. Text in Illustration
Standard Resistance:
HINT: Do not disconnect the shift lock control unit assembly connector. If the result is not as specified, replace the shift lock control unit assembly. |
|
3. INSPECT TRANSMISSION CONTROL SWITCH
(a) Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position. Text in Illustration
Standard Resistance:
If the result is not as specified, replace the shift lock control unit assembly. |
|
4. INSPECT SHIFT LOCK SOLENOID
(a) Disconnect the shift lock solenoid connector.
(b) Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position. Text in Illustration
Standard Resistance:
If the result is not as specified, replace the shift lock control unit assembly. |
|
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
1 (SLS+) - 2 (SLS-) |
Always |
112 Ω |
If the result is not as specified, replace the shift lock control unit assembly.
Data List / Active Test
DATA LIST / ACTIVE TEST
1. DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches,
sensors, actuators and other items to be read without removing any parts. This non-intrusive
inspection can be very useful bec ...
High Mounted Stop Light Assembly
Components
COMPONENTS
ILLUSTRATION
Removal
REMOVAL
PROCEDURE
1. REMOVE CENTER STOP LIGHT ASSEMBLY
(a) Using a short screwdriver, remove the 2 screws.
(b) Disconnect the connector and remov ...
Precaution
PRECAUTION
NOTICE:
When disconnecting the cable from the negative (-) battery terminal, initialize
the following systems after the cable is reconnected.
System Name
See Procedure
Back Door Closer System
...