Toyota Venza manuals

Toyota Venza: Ignition Switch

Components

COMPONENTS

ILLUSTRATION


Removal

REMOVAL

PROCEDURE

1. REMOVE LOWER STEERING COLUMN COVER


2. REMOVE UPPER STEERING COLUMN COVER


3. REMOVE IGNITION SWITCH

(a) Remove the 2 screws and ignition switch.


(b) Disconnect the connector.


(c) Disconnect the connector clamp from the ignition switch.

Inspection

INSPECTION

PROCEDURE

1. INSPECT IGNITION SWITCH

(a) Measure the switch resistance.

Standard Resistance:

Tester Connection

Switch Position

Specified Condition

Between all terminals

LOCK

10 kΩ or higher

2 (AM1) - 3 (ACC)

ACC

Below 1 Ω

2 (AM1) - 3 (ACC)

ON

2 (AM1) - 4 (IG1)

6 (IG2) - 7 (AM2)

1 (ST1) - 2 (AM1)

START

2 (AM1) - 4 (IG1)

6 (IG2) - 7 (AM2)

7 (AM2) - 8 (ST2)

If the result is not as specified, replace the switch assembly.


Installation

INSTALLATION

PROCEDURE

1. INSTALL IGNITION SWITCH

(a) Connect the connector.


(b) Install the connector clamp to the ignition switch.

(c) Install the ignition switch with the 2 screws.


2. INSTALL UPPER STEERING COLUMN COVER


3. INSTALL LOWER STEERING COLUMN COVER


Installation
INSTALLATION PROCEDURE 1. INSTALL ENGINE SWITCH (a) Attach the 2 claws to install the engine switch. 2. INSTALL LOWER INSTRUMENT PANEL FI ...

Relay
On-vehicle Inspection ON-VEHICLE INSPECTION PROCEDURE 1. INSPECT STARTER RELAY (a) Measure the resistance according to the value(s) in the table below. Standard Resistance: ...

Other materials about Toyota Venza:

Removal
REMOVAL PROCEDURE 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system. NOTICE: When disconnecting the cable, some systems ne ...

Automatic air conditioning system
Airflow and outlets are automatically adjusted according to the temperature setting.  ► Control panel ► Multi-information display (TFT type) The settings display will differ according to the situation. If is pressed while in automat ...

Precaution
PRECAUTION 1. PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE BATTERY TERMINAL NOTICE: When disconnecting the cable from the negative (-) battery terminal, initialize the following system after the terminal is reconnected: System Name ...