DESCRIPTION
The evaporator temperature sensor is installed on the evaporator in the air conditioning unit to detect the cooled air temperature that has passed through the evaporator and to control the air conditioning. It sends appropriate signals to the A/C amplifier. The resistance of the evaporator temperature sensor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the evaporator temperature sensor and reads voltage changes as the resistance of the evaporator temperature sensor changes. This sensor is used for frost prevention.
DTC No. |
DTC Detection Condition |
Trouble Area |
---|---|---|
B1413/13 |
Open or short in evaporator temperature sensor circuit |
|
WIRING DIAGRAM
PROCEDURE
1. |
READ VALUE USING TECHSTREAM |
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body / Air Conditioner / Data List.
(e) Check the value(s) by referring to the table below.
Air Conditioner
Tester Display |
Measurement Item/Range |
Normal Condition |
Diagnostic Note |
---|---|---|---|
Evaporator Fin Thermistor |
Evaporator temperature sensor / Min.: -30°C (-22°F) Max.: 59.6°C (139.28°F) |
Actual evaporator temperature displayed |
- |
OK:
The display is as specified in the Normal Condition column.
Result |
Proceed to |
---|---|
NG |
A |
OK (When troubleshooting according to Problem Symptoms Table) |
B |
OK (When troubleshooting according to the DTC) |
C |
B |
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE |
C |
REPLACE A/C AMPLIFIER |
|
2. |
INSPECT EVAPORATOR TEMPERATURE SENSOR |
(a) Remove the evaporator temperature sensor.
(b) Disconnect the evaporator temperature sensor connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
e2-1 - e2-2 |
-10°C (14°F) |
7.30 to 9.10 kΩ |
e2-1 - e2-2 |
-5°C (23°F) |
5.65 to 6.95 kΩ |
e2-1 - e2-2 |
0°C (32°F) |
4.40 to 5.35 kΩ |
e2-1 - e2-2 |
5°C (41°F) |
3.40 to 4.15 kΩ |
e2-1 - e2-2 |
10°C (50°F) |
2.70 to 3.25 kΩ |
e2-1 - e2-2 |
15°C (59°F) |
2.14 to 2.58 kΩ |
e2-1 - e2-2 |
20°C (68°F) |
1.71 to 2.05 kΩ |
e2-1 - e2-2 |
25°C (77°F) |
1.38 to 1.64 kΩ |
e2-1 - e2-2 |
30°C (86°F) |
1.11 to 1.32 kΩ |
NOTICE:
HINT:
As the temperature increases, the resistance decreases (see the graph).
Text in Illustration
*1 |
Component without harness connected (Evaporator Temperature Sensor) |
*2 |
Sensing Portion |
NG |
REPLACE EVAPORATOR TEMPERATURE SENSOR |
|
3. |
INSPECT AIR CONDITIONING HARNESS (A/C AMPLIFIER - EVAPORATOR TEMPERATURE SENSOR) |
(a) Remove the air conditioning harness. |
|
(b) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|
|
OK |
REPLACE A/C AMPLIFIER |
NG |
REPLACE AIR CONDITIONING HARNESS |
Installation
INSTALLATION
PROCEDURE
1. INSTALL REAR COMBINATION LIGHT ASSEMBLY
(a) Engage the guide and 2 pins, and install the rear combination light
assembly as shown in the illustration.
Text in Illustration
*1
P ...
Meter Illumination is Always Dark
DESCRIPTION
In this circuit, the meter CPU receives auto dimmer signals from the main body
ECU (driver side junction block assembly) using the CAN communication system (CAN
No. 1 Bus). When the meter CPU receives an auto dimmer signal, it dims the meter
...
Panel Switches do not Function
PROCEDURE
1.
CHECK PANEL SWITCH
(a) Check for foreign matter around the switches that might prevent operation.
OK:
No foreign matter is found.
NG
REMOVE ANY FOREIGN MATTER FOUND
...