DESCRIPTION

  • A pulse sensor is built into the power back door ECU (power back door motor unit) to detect foreign objects and the back door position. The pulse sensor monitors the operating speed of the back door to detect foreign objects. The pulse sensor is also used to monitor the back door position. If a pulse signal that is out of the normal range is output, the power back door ECU (power back door motor unit) will store DTC B2222.
  • If DTC B2222 is stored, the power back door system will be turned off and the back door will be switched to manual operation mode (not electrically controlled).
  • In order to restore the power back door system to normal operation mode, first solve the problem indicated by DTC B2222 and then fully close the back door manually (reset operation).

    DTC No.

    DTC Detection Condition

    Trouble Area

    B2222

    The power back door ECU (Power back door motor unit) does not operate.

    Power back door ECU (Power back door motor unit)

PROCEDURE

1.

CHECK FOR DTC

(a) Check for DTCs (See page ).


(b) Clear the DTCs (See page ).


(c) Recheck for DTCs (See page ).


OK:

DTC B2222 is not output.


OK

USE SIMULATION METHOD TO CHECK


NG

REPLACE POWER BACK DOOR ECU (POWER BACK DOOR MOTOR UNIT)

Diagnostic Trouble Code Chart
DIAGNOSTIC TROUBLE CODE CHART HINT: If a trouble code is displayed during the DTC check, inspect the trouble areas listed below for that code. For details of the code, refer to the following " ...

Back Door Motor Clutch Malfunction (B2225)
DESCRIPTION When an electrical malfunction (open or short) is detected in the clutch circuit of the power back door ECU (power back door motor unit) while the power back door is operating, the po ...

Other materials about Toyota Venza:

Inspection
INSPECTION PROCEDURE 1. INSPECT FUEL INJECTOR ASSEMBLY (a) Measure the resistance according to the value(s) in the table below. Standard Resistance: Tester Connection Condition Specified C ...

Crankshaft Position - Camshaft Position Correlation (Bank 1 Sensor A) (P0016,P0017)
DESCRIPTION In the VVT (Variable Valve Timing) system, the appropriate intake and exhaust valve open and close timing is controlled by the ECM. The ECM performs intake and exhaust valve control by performing the following: 1) controlling the camshaft and ...

Power back door switch (vehicles with power back door)
Push the switch to close. Pressing the switch again while the power back door is closing will cause it to open again. However, the reverse operation cannot be performed for the first second after pressing the switch to close the door. The back door ca ...

© 2016-2020 Copyright www.tovenza.com

0.2226